Pagina 1 - PRESSURE CONTROL PUMPS

BOOSTAMATICPRESSURE CONTROL PUMPSOPERATING INSTRUCTIONSPlease leave this instruction booklet with the pump as it contains maintenance and safety infor

Pagina 2 - APPLICATION

- 10 -Cont ...Pump Mounted Above Liquid Source (Suction Lift Installation)The pumps can be used in a suction lift installation providing the height of

Pagina 3 - PRODUCT DESCRIPTION

- 11 -Certain installations may require additional earthing requirements such as supplementary equipotential bonding. Reference should be made to the

Pagina 4 - LIMITS OF APPLICATION

- 12 -Cont ...Wiring The Wires in the mains lead (supply cord) are coloured in accordance with the following code:Green and Yellow: Earth Blue: N

Pagina 5 - PUMP CONNECTIONS

- 13 -Cont ...Supply Cord ReplacementIf the supply cord needs to be replaced, cord selection should be chosen in accordance with the current involved,

Pagina 6 - PRE-INSTALLATION ASSEMBLY

- 14 -Cont ...1. System Flushing This pump-set incorporates plastic components that must not come into contact with solder flux, acid-based desc

Pagina 7

- 15 -Cont ...5. Starting The Pump a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then sto

Pagina 8 - tanks at all time

- 16 -Cont ...5. As water is heated scale deposits are released in areas of hard water (usually south of a line between the Wash and Bristol Cha

Pagina 9

- 17 -Cont ...TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check wiring connections.Check a

Pagina 10 - Fig. 12

- 18 -Dry Run ProtectionThis pump is fitted with a safety control circuit, which will detect the following fault condition:  Dry running caused by wa

Pagina 11 - Earthing

- 19 -ENVIRONMENT PROTECTIONYour appliance contains valuable materials which can be recovered or recycled.At the end of the products’ useful life, ple

Pagina 12 - Wiring Diagrams

- 2 -PRESSURE CONTROL MODELSBoostamatic 4000Boostamatic 6000Boostamatic K7-2 Boostamatic L5-4SBoostamatic L7-4SBoostamatic T6-2Boostamatic T12-2INDEX

Pagina 13 - Supply Cord Extension

Stuart Turner Ltd, Henley-on-Thames, Oxfordshire RG9 2AD ENGLAND Tel: +44 (0) 1491 572655, Fax: +44 (0) 1491 573704email: pumps@stuart-turn

Pagina 14 - Cont

- 3 -Cont ...PRODUCT DESCRIPTIONElectric motor driven pump complete with flow switch, pressure switch, pressure vessel and electronic control.MotorCla

Pagina 15 - MAINTENANCE

- 4 -Cont ...Notes: Max. viscosity: 9.5 centistokes (Redwood No 1 scale).Max. ambient air temp: 40°C* With footvalve fitted.** Max working pressure

Pagina 16

- 5 -Cont ...PUMP CONNECTIONSModel Inlet(Pump)Outlet Fig. No.4000 G 1 Female G 1 Female 26000 G 1 Female G 1 Female 2K7-2 G 1 Female G 1 Female 4L5-4S

Pagina 17 - TROUBLE SHOOTING GUIDE

- 6 -Cont ...PRE-INSTALLATION ASSEMBLYPressure Check and Assembly of Pressure Vessela) Certain models are supplied in two parts, the main pump and th

Pagina 18 - Flow Switch Circuit Test

- 7 -Cont ...Re-positioning of Pressure VesselThe pressure vessel can be rotated to alternative positions (Figs. 7, 8 & 9) in the event of the fac

Pagina 19 - YOUR 1 YEAR GUARANTEE

- 8 -Cont ...SITING OF THE PUMP/PIPEWORKWARNINGS:  Pump Location If possible site the pump in a location where in the unlikely event of a liqui

Pagina 20 - Business Development Director

- 9 -To prevent loss of pressure through pipework, use pipe size to match pump whenever possible, minimising 90° bends.It must be ensured that storage